Fire Fighting Cylinder

Fire Fighting Cylinder

Standard:GB5099-2017 Specification:279-6.0-(50-90)L-17.2MPa
Send Inquiry
Chat Now

Description

Technical Parameters

The Fire Fighting Cylinder can be used for gas fires before the gas source is cut off, liquid fires or solid fires of fusible materials such as asphalt and paraffin, fires on common solid surfaces such as cotton cloth and fabrics, including electrical fires of precision instruments. It cannot be used for fires of chemicals containing oxidants such as nitrocellulose and gunpowder, fires of active metals such as potassium, sodium, magnesium, titanium, and zirconium, and fires of metal cyanides such as potassium cyanide and sodium cyanide.

 

In the hands of trained personnel, portable fire extinguishers are an important tool in protecting people and property from fire in its early stages. When using a fire extinguisher or choosing to install one, it is important to understand the characteristics of the different extinguishers. This blog will cover the different types of fire extinguishers by breaking them down by the extinguishing agent (the extinguishing agent is the material inside the extinguisher that is used to put out the fire).

 

Water is the primary liquid used in these extinguishers, although sometimes other additives are also included. A drawback for pure water fire extinguishers is that it is not suitable for use in freezing conditions since the water inside will freeze and render the extinguisher unusable. Certain types of water fire extinguishers contain antifreeze which will allow the extinguisher to be used in freezing conditions. Water type fire extinguishers can also sometimes contain wetting agents which are designed to help increase its effectiveness against fire. These extinguishers are intended primarily for use on Class A fires.

05

08

14

20

 

29

Hot Tags: fire fighting cylinder, China fire fighting cylinder manufacturers, suppliers, factory, UNISO9809 1 Cylinder, 80L Cylinder, 27L Cylinder, 30L Cylinder, Working Pressure 200bar Cylinder, ISO9809 2 TPED Cylinder

No.

Process

Type

OD(mm)

V(L)

WP(MPa)

1

Billet

WZⅠ-219-(20-40)-15A

219

20-40

15

2

WGⅠ-229-(20-50)-20A

229

20-50

20

3

WGⅠ-229-(20-50)-20AⅠ

229

20-50

20

4

WGⅠ-229-(20-50)-20AⅡ

229

20-50

20

5

WGⅠ-232-(23-50)-15A

232

23-50

15

6

Tube

WGⅡ-140-(4-12)-20A

140

4-12

20

7

WZⅡ-232-(23-50)-15A

232

23-50

15

8

WGⅡ-229-(20-50)-20A

229

20-50

20

9

WGⅡ-229-(20-50)-20AⅠ

229

20-50

20

10

WZⅡ-267-(60-80)-15A

267

60-80

15

11

WGⅡ-279-(50-90)-20A

279

50-90

20